Development and validation of the Augsburg Nasopharyngeal Applicator

  • Purpose This study evaluates the Augsburg Nasopharyngeal Applicator (ANA), a novel nasal brachytherapy device designed for early-stage nasopharyngeal carcinoma (T1-T2 stages). ANA leverages nasal anatomy to overcome limitations of oral applicators, optimizing tumor targeting while sparing adjacent tissues, such as the soft palate and oral mucosa. Materials and Methods ANA was developed using sagittal computed tomography (CT)-based anatomical measurements and computer-aided design (CAD) modeling. Structural integrity was validated through nonlinear finite element analysis (FEA), mechanical stress testing (including Euler buckling tests), and displacement testing (30 min vibration at 5 Hz with 2 cm amplitude). Dosimetry was verified using radiochromic film with 3%/3 mm gamma analysis criteria, following the TG-43 formalism for dose calculation. Insertion feasibility was assessed in a postmortem model under institutional autopsy protocols. Results ANA (with nylon 6/6 catheter)Purpose This study evaluates the Augsburg Nasopharyngeal Applicator (ANA), a novel nasal brachytherapy device designed for early-stage nasopharyngeal carcinoma (T1-T2 stages). ANA leverages nasal anatomy to overcome limitations of oral applicators, optimizing tumor targeting while sparing adjacent tissues, such as the soft palate and oral mucosa. Materials and Methods ANA was developed using sagittal computed tomography (CT)-based anatomical measurements and computer-aided design (CAD) modeling. Structural integrity was validated through nonlinear finite element analysis (FEA), mechanical stress testing (including Euler buckling tests), and displacement testing (30 min vibration at 5 Hz with 2 cm amplitude). Dosimetry was verified using radiochromic film with 3%/3 mm gamma analysis criteria, following the TG-43 formalism for dose calculation. Insertion feasibility was assessed in a postmortem model under institutional autopsy protocols. Results ANA (with nylon 6/6 catheter) withstood displacements up to 30 mm without failure. Simulated motion tests demonstrated positional stability (<1 mm displacement). Dosimetry achieved a 97.5% gamma pass rate (clinical acceptability threshold: 95%), with the 20 mm curvature configuration reducing soft palate doses by >50% compared to standard oral applicators (e.g., Rotterdam design). Postmortem insertion was completed in 10 min, with endoscopic confirmation of positioning accuracy within 1 mm. Conclusion ANA demonstrates precise positioning, mechanical stability under simulated physiological motion (<1 mm displacement), and clinically significant dose sparing (>50% reduction to the soft palate with the 20 mm curvature configuration). Its nasal approach and anatomical adaptability position it as a promising alternative to oral applicators. These proof-of-concept findings support the need for phase I/II clinical trials to evaluate safety and efficacy in patients.show moreshow less

Download full text files

Export metadata

Statistics

Number of document requests

Additional Services

Share in Twitter Search Google Scholar
Metadaten
Author:Jerome Jean-Joseph, Christoph WesterhausenORCiDGND, Johannes DoescherORCiDGND, Bruno MaerklORCiDGND, Zoha Roushan, Maria NeuORCiDGND, Tilman Janzen, Klaus-Henning KahlORCiDGND, Georg StuebenGND, Nikolaos Balagiannis
Frontdoor URLhttps://opus.bibliothek.uni-augsburg.de/opus4/124962
ISSN:2452-1094OPAC
Parent Title (English):Advances in Radiation Oncology
Publisher:Elsevier BV
Type:Article
Language:English
Year of first Publication:2025
Publishing Institution:Universität Augsburg
Release Date:2025/09/09
First Page:101896
DOI:https://doi.org/10.1016/j.adro.2025.101896
Institutes:Medizinische Fakultät
Medizinische Fakultät / Universitätsklinikum
Medizinische Fakultät / Lehrstuhl für Allgemeine und Spezielle Pathologie
Medizinische Fakultät / Lehrstuhl für Hals-, Nasen- und Ohrenheilkunde
Medizinische Fakultät / Lehrstuhl für Strahlentherapie
Medizinische Fakultät / Professur für Physiologie (Westerhausen)
Dewey Decimal Classification:6 Technik, Medizin, angewandte Wissenschaften / 61 Medizin und Gesundheit / 610 Medizin und Gesundheit
Latest Publications (not yet published in print):Aktuelle Publikationen (noch nicht gedruckt erschienen)
Licence (German):CC-BY-NC-ND 4.0: Creative Commons: Namensnennung - Nicht kommerziell - Keine Bearbeitung (mit Print on Demand)