The magnetic properties of electrical pulses delivered by deep-brain stimulation systems

  • The aim of this article is to analyze the magnetic field properties for both the monopolar and bipolar electrode configurations of deep-brain stimulation electrodes using 3-D magnetic field measurements and to investigate if the magnetic measurements enable a localization of the electrode as a proof of concept. Therefore, a simplified head phantom with an integrated deep-brain stimulation electrode was created to measure the magnetic flux densities in all the three dimensions with a fluxgate magnetometer over a sensor trajectory of measuring points inside the magnetically shielded chamber. The magnitude of the magnetic flux density for monopolar stimulation and bipolar stimulation is in the nT and pT ranges for the frequency 160 Hz, depending on the stimulation amplitude and on the distance between the sensor and the electrode. The field distributions show a linear decline in the magnetic field for the monopolar and a quadratic decline for the bipolar stimulation. We were able toThe aim of this article is to analyze the magnetic field properties for both the monopolar and bipolar electrode configurations of deep-brain stimulation electrodes using 3-D magnetic field measurements and to investigate if the magnetic measurements enable a localization of the electrode as a proof of concept. Therefore, a simplified head phantom with an integrated deep-brain stimulation electrode was created to measure the magnetic flux densities in all the three dimensions with a fluxgate magnetometer over a sensor trajectory of measuring points inside the magnetically shielded chamber. The magnitude of the magnetic flux density for monopolar stimulation and bipolar stimulation is in the nT and pT ranges for the frequency 160 Hz, depending on the stimulation amplitude and on the distance between the sensor and the electrode. The field distributions show a linear decline in the magnetic field for the monopolar and a quadratic decline for the bipolar stimulation. We were able to reconstruct the magnetic field using multiple recording sites. As the magnetic field of deep-brain stimulation can be measured and its field strength can be reconstructed, it is feasible to estimate the strength of the field within the limits of programmable stimulation parameters and distance between the sensor and the electrode. The presented results are intended as preliminary work for the further development of electrode localization methods using magnetic measurements. As an example of the feasibility of electrode localization, this article presents a bipolar measurement that creates a more focused spatial field distribution and results in an accurate localization.show moreshow less

Download full text files

  • 110138pp.pdfeng
    (5081KB)

    Postprint. © 2020 IEEE. Personal use of this material is permitted. Permission from IEEE must be obtained for all other uses, in any current or future media, including reprinting/republishing this material for advertising or promotional purposes, creating new collective works, for resale or redistribution to servers or lists, or reuse of any copyrighted component of this work in other works.

Export metadata

Statistics

Number of document requests

Additional Services

Share in Twitter Search Google Scholar
Metadaten
Author:Mevlut Yalaz, Alexander Teplyuk, Muthuraman MuthuramanORCiDGND, Gunther Deuschl, Michael Hoft
URN:urn:nbn:de:bvb:384-opus4-1101383
Frontdoor URLhttps://opus.bibliothek.uni-augsburg.de/opus4/110138
ISSN:0018-9456OPAC
ISSN:1557-9662OPAC
Parent Title (English):IEEE Transactions on Instrumentation and Measurement
Publisher:Institute of Electrical and Electronics Engineers (IEEE)
Place of publication:New York, NY
Type:Article
Language:English
Year of first Publication:2020
Publishing Institution:Universität Augsburg
Release Date:2023/12/13
Tag:Electrical and Electronic Engineering; Instrumentation
Volume:69
Issue:7
First Page:4303
Last Page:4313
DOI:https://doi.org/10.1109/tim.2019.2945744
Institutes:Fakultät für Angewandte Informatik
Fakultät für Angewandte Informatik / Institut für Informatik
Fakultät für Angewandte Informatik / Institut für Informatik / Professur für Informatik in der Medizintechnik
Dewey Decimal Classification:0 Informatik, Informationswissenschaft, allgemeine Werke / 00 Informatik, Wissen, Systeme / 004 Datenverarbeitung; Informatik
Licence (German):Deutsches Urheberrecht