Hemodynamic assessment of partial mechanical circulatory support: data derived from computed tomography angiographic images and computational fluid dynamics

  • Partial mechanical circulatory support represents a new concept for the treatment of advanced heart failure. The Circulite Synergy Micro Pump®, where the inflow cannula is connected to the left atrium and the outflow cannula to the right subclavian artery, was one of the first devices to introduce this concept to the clinic. Using computational fluid dynamics (CFD) simulations, hemodynamics in the aortic tree was visualized and quantified from computed tomography angiographic (CTA) images in two patients. A realistic computational model was created by integrating flow information from the native heart and from the Circulite device. Diastolic flow augmentation in the descending aorta but competing/antagonizing flow patterns in the proximal innominate artery was observed. Velocity time curves in the ascending aorta correlated well with those in the left common carotid, the left subclavian and the descending aorta but poorly with the one in the innominate. Our results demonstrate that CFDPartial mechanical circulatory support represents a new concept for the treatment of advanced heart failure. The Circulite Synergy Micro Pump®, where the inflow cannula is connected to the left atrium and the outflow cannula to the right subclavian artery, was one of the first devices to introduce this concept to the clinic. Using computational fluid dynamics (CFD) simulations, hemodynamics in the aortic tree was visualized and quantified from computed tomography angiographic (CTA) images in two patients. A realistic computational model was created by integrating flow information from the native heart and from the Circulite device. Diastolic flow augmentation in the descending aorta but competing/antagonizing flow patterns in the proximal innominate artery was observed. Velocity time curves in the ascending aorta correlated well with those in the left common carotid, the left subclavian and the descending aorta but poorly with the one in the innominate. Our results demonstrate that CFD may be useful in providing a better understanding of the main flow patterns in mechanical circulatory support devices.…show moreshow less

Download full text files

Export metadata

Statistics

Number of document requests

Additional Services

Share in Twitter Search Google Scholar
Metadaten
Author:Christof Karmonik, Sasan Partovi, Fabian Rengier, Hagen Meredig, Mina Berty Farag, Matthias Müller-Eschner, Rawa ArifORCiDGND, Aron-Frederik Popov, Hans-Ulrich Kauczor, Matthias Karck, Arjang Ruhparwar
URN:urn:nbn:de:bvb:384-opus4-1335909
Frontdoor URLhttps://opus.bibliothek.uni-augsburg.de/opus4/133590
ISBN:2223-3652OPAC
Parent Title (English):Cardiovascular Diagnosis and Therapy
Publisher:AME Publishing Company
Place of publication:Hong Kong
Type:Article
Language:English
Date of Publication (online):2026/09/28
Year of first Publication:2015
Publishing Institution:Universität Augsburg
Release Date:2026/10/01
Volume:5
Issue:2
First Page:160
Last Page:165
DOI:https://doi.org/10.3978/j.issn.2223-3652.2015.03.03
Institutes:Medizinische Fakultät
Medizinische Fakultät / Universitätsklinikum
Medizinische Fakultät / Professur für Herzchirurgie
Dewey Decimal Classification:6 Technik, Medizin, angewandte Wissenschaften / 61 Medizin und Gesundheit / 610 Medizin und Gesundheit
Licence (German):CC-BY-NC-ND 4.0: Creative Commons: Namensnennung - Nicht kommerziell - Keine Bearbeitung