• Deutsch
Login

Open Access

  • Home
  • Search
  • Browse
  • Publish/report a document
  • Help

Refine

Has Fulltext

  • yes (12)

Author

  • Higuchi, Takahiro (12)
  • Lapa, Constantin (12)
  • Gorin, Michael A. (11)
  • Pienta, Kenneth J. (11)
  • Pomper, Martin G. (11)
  • Rowe, Steven P. (11)
  • Werner, Rudolf A. (11)
  • Buck, Andreas K. (10)
  • Bundschuh, Lena (8)
  • Javadi, Mehrbod S. (7)
+ more

Year of publication

  • 2023 (2)
  • 2022 (1)
  • 2021 (1)
  • 2020 (1)
  • 2019 (2)
  • 2018 (4)
  • 2017 (1)

Document Type

  • Article (12)

Language

  • English (12)

Keywords

  • Radiology Nuclear Medicine and imaging (4)
  • Oncology (3)
  • Urology (2)
  • Biomedical Engineering (1)
  • Biotechnology (1)
  • Cancer Research (1)
  • Condensed Matter Physics (1)
  • General Medicine (1)
  • Molecular Medicine (1)
  • Radiology, Nuclear Medicine and imaging (1)
+ more

Institute

  • Lehrstuhl für Nuklearmedizin (12)
  • Medizinische Fakultät (12)
  • Universitätsklinikum (12)
  • Nachhaltigkeitsziele (3)
  • Ziel 3 - Gesundheit und Wohlergehen (3)

12 search hits

  • 1 to 12
  • 10
  • 20
  • 50
  • 100

Sort by

  • Year
  • Year
  • Title
  • Title
  • Author
  • Author
SSTR-RADS version 1.0 as a reporting system for SSTR PET imaging and selection of potential PRRT candidates: a proposed standardization framework (2018)
Werner, Rudolf A. ; Solnes, Lilja B. ; Javadi, Mehrbod S. ; Weich, Alexander ; Gorin, Michael A. ; Pienta, Kenneth J. ; Higuchi, Takahiro ; Buck, Andreas K. ; Pomper, Martin G. ; Rowe, Steven P. ; Lapa, Constantin
Interobserver agreement for the standardized reporting system PSMA-RADS 1.0 on 18F-DCFPyL PET/CT imaging (2018)
Werner, Rudolf A. ; Bundschuh, Ralph A. ; Bundschuh, Lena ; Javadi, Mehrbod S. ; Leal, Jeffrey P. ; Higuchi, Takahiro ; Pienta, Kenneth J. ; Buck, Andreas K. ; Pomper, Martin G. ; Gorin, Michael A. ; Lapa, Constantin ; Rowe, Steven P.
Follow-up of lesions with equivocal radiotracer uptake on PSMA-targeted PET in patients with prostate cancer: predictive values of the PSMA-RADS-3A and PSMA-RADS-3B categories (2019)
Yin, Yafu ; Werner, Rudolf A. ; Higuchi, Takahiro ; Lapa, Constantin ; Pienta, Kenneth J. ; Pomper, Martin G. ; Gorin, Michael A. ; Rowe, Steven P.
Molecular imaging reporting and data systems (MI-RADS): a generalizable framework for targeted radiotracers with theranostic implications (2018)
Werner, Rudolf A. ; Bundschuh, Ralph A. ; Bundschuh, Lena ; Javadi, Mehrbod S. ; Higuchi, Takahiro ; Weich, Alexander ; Sheikhbahaei, Sara ; Pienta, Kenneth J. ; Buck, Andreas K. ; Pomper, Martin G. ; Gorin, Michael A. ; Lapa, Constantin ; Rowe, Steven P.
A voice from the past: rediscovering the Virchow node with prostate-specific membrane antigen-targeted 18 F-DCFPyL positron emission tomography imaging (2018)
Werner, Rudolf A. ; Andree, Christian ; Javadi, Mehrbod S. ; Lapa, Constantin ; Buck, Andreas K. ; Higuchi, Takahiro ; Pomper, Martin G. ; Gorin, Michael A. ; Rowe, Steven P. ; Pienta, Kenneth J.
Patterns of uptake of prostate-specific membrane antigen (PSMA)-targeted 18F-DCFPyL in peripheral ganglia (2017)
Werner, Rudolf A. ; Sheikhbahaei, Sara ; Jones, Krystyna M. ; Javadi, Mehrbod S. ; Solnes, Lilja B. ; Ross, Ashley E. ; Allaf, Mohamad E. ; Pienta, Kenneth J. ; Lapa, Constantin ; Buck, Andreas K. ; Higuchi, Takahiro ; Pomper, Martin G. ; Gorin, Michael A. ; Rowe, Steven P.
Semiquantitative parameters in PSMA-targeted PET imaging with [18F]DCFPyL: impact of tumor burden on normal organ uptake (2020)
Werner, Rudolf A. ; Bundschuh, Ralph A. ; Bundschuh, Lena ; Lapa, Constantin ; Yin, Yafu ; Javadi, Mehrbod S. ; Buck, Andreas K. ; Higuchi, Takahiro ; Pienta, Kenneth J. ; Pomper, Martin G. ; Lodge, Martin A. ; Gorin, Michael A. ; Rowe, Steven P.
Novel structured reporting systems for theranostic radiotracers (2019)
Werner, Rudolf A. ; Bundschuh, Ralph A. ; Bundschuh, Lena ; Fanti, Stefano ; Javadi, Mehrbod S. ; Higuchi, Takahiro ; Weich, Alexander ; Pienta, Kenneth J. ; Buck, Andreas K. ; Pomper, Martin G. ; Gorin, Michael A. ; Herrmann, Ken ; Lapa, Constantin ; Rowe, Steven P.
Test-retest reproducibility of radiomic features on PSMA-targeted F-18-DCFPyL PET/CT in patients with metastatic prostate cancer [Abstract] (2021)
Werner, Rudolf ; Habacha, Bilel ; Bundschuh, Lena ; Higuchi, Takahiro ; Serfling, Sebastian ; Derlin, Thorsten ; Essler, Markus ; Lapa, Constantin ; Pienta, Kenneth ; Buck, Andreas ; Eisenberger, Mario ; Markowski, Mark ; Lodge, Martin ; Pomper, Martin ; Gorin, Michael ; Rowe, Steven ; Bundschuh, Ralph
Test-retest repeatability of organ uptake on PSMA‐targeted 18F‐DCFPyL PET/CT in patients with prostate cancer (2023)
Werner, Rudolf A. ; Lütje, Susanne ; Habacha, Bilêl ; Bundschuh, Lena ; Higuchi, Takahiro ; Buck, Andreas K. ; Kosmala, Aleksander ; Lapa, Constantin ; Essler, Markus ; Lodge, Martin A. ; Pienta, Kenneth J. ; Eisenberger, Mario A. ; Markowski, Mark C. ; Gorin, Michael A. ; Pomper, Martin G. ; Rowe, Steven P. ; Bundschuh, Ralph Alexander
Objectives We evaluated 18F-DCFPyL test–retest repeatability of uptake in normal organs. Methods Twenty-two prostate cancer (PC) patients underwent two 18F-DCFPyL PET scans within 7 days within a prospective clinical trial (NCT03793543). In both PET scans, uptake in normal organs (kidneys, spleen, liver, and salivary and lacrimal glands) was quantified. Repeatability was determined by using within-subject coefficient of variation (wCOV), with lower values indicating improved repeatability. Results For SUVmean, repeatability was high for kidneys, spleen, liver, and parotid glands (wCOV, range: 9.0%–14.3%) and lower for lacrimal (23.9%) and submandibular glands (12.4%). For SUVmax, however, the lacrimal (14.4%) and submandibular glands (6.9%) achieved higher repeatability, while for large organs (kidneys, liver, spleen, and parotid glands), repeatability was low (range: 14.1%–45.2%). Conclusion We found acceptable repeatability of uptake on 18F-DCFPyL PET for normal organs, in particular for SUVmean in the liver or parotid glands. This may have implications for both PSMA-targeted imaging and treatment, as patient selection for radioligand therapy and standardized frameworks for scan interpretation (PROMISE, E-PSMA) rely on uptake in those reference organs.
High SUVs have more robust repeatability in patients with metastatic prostate cancer: results from a prospective test-retest cohort imaged with 18F-DCFPyL (2022)
Werner, Rudolf A. ; Habacha, Bilêl ; Lütje, Susanne ; Bundschuh, Lena ; Higuchi, Takahiro ; Hartrampf, Philipp ; Serfling, Sebastian E. ; Derlin, Thorsten ; Lapa, Constantin ; Buck, Andreas K. ; Essler, Markus ; Pienta, Kenneth J. ; Eisenberger, Mario A. ; Markowski, Mark C. ; Shinehouse, Laura ; AbdAllah, Rehab ; Salavati, Ali ; Lodge, Martin A. ; Pomper, Martin G. ; Gorin, Michael A. ; Bundschuh, Ralph A. ; Rowe, Steven P.
Lack of repeatability of radiomic features derived from PET scans: results from a 18F‐DCFPyL test–retest cohort (2023)
Werner, Rudolf A. ; Habacha, Bilêl ; Lütje, Susanne ; Bundschuh, Lena ; Kosmala, Alekandser ; Essler, Markus ; Derlin, Thorsten ; Higuchi, Takahiro ; Lapa, Constantin ; Buck, Andreas K. ; Pienta, Kenneth J. ; Lodge, Martin A. ; Eisenberger, Mario A. ; Markowski, Mark C. ; Pomper, Martin G. ; Gorin, Michael A. ; Frey, Eric C. ; Rowe, Steven P. ; Bundschuh, Ralph A.
Objectives PET-based radiomic metrics are increasingly utilized as predictive image biomarkers. However, the repeatability of radiomic features on PET has not been assessed in a test–retest setting. The prostate-specific membrane antigen-targeted compound 18F-DCFPyL is a high-affinity, high-contrast PET agent that we utilized in a test-retest cohort of men with metastatic prostate cancer (PC). Methods Data of 21 patients enrolled in a prospective clinical trial with histologically proven PC underwent two 18F-DCFPyL PET scans within 7 days, using identical acquisition and reconstruction parameters. Sites of disease were segmented and a set of 29 different radiomic parameters were assessed on both scans. We determined repeatability of quantification by using Pearson's correlations, within-subject coefficient of variation (wCOV), and Bland–Altman analysis. Results In total, 230 lesions (177 bone, 38 lymph nodes, 15 others) were assessed on both scans. For all investigated radiomic features, a broad range of inter-scan correlation was found (r, 0.07–0.95), with acceptable reproducibility for entropy and homogeneity (wCOV, 16.0% and 12.7%, respectively). On Bland–Altman analysis, no systematic increase or decrease between the scans was observed for either parameter (±1.96 SD: 1.07/−1.30, 0.23/−0.18, respectively). The remaining 27 tested radiomic metrics, however, achieved unacceptable high wCOV (≥21.7%). Conclusion Many common radiomic features derived from a test–retest PET study had poor repeatability. Only Entropy and homogeneity achieved good repeatability, supporting the notion that those image biomarkers may be incorporated in future clinical trials. Those radiomic features based on high frequency aspects of images appear to lack the repeatability on PET to justify further study.
  • 1 to 12

OPUS4 Logo

  • Contact
  • Imprint
  • Sitelinks